CQU Reliability assessment of wind-solar PV integrated distribution system using electrical loss minimization technique.pdf (761.86 kB)
Reliability assessment of wind-solar PV integrated distribution system using electrical loss minimization technique
journal contribution
posted on 2022-11-09, 04:34 authored by S Kumar, K Sarita, ASS Vardhan, RM Elavarasan, RK Saket, Narottam DasNarottam DasThis article presents the Reliability Assessment (RA) of renewable energy interfaced Electrical Distribution System (EDS) considering the electrical loss minimization (ELM). ELM aims at minimizing the detrimental effect of real power and reactive power losses in the EDS. Some techniques, including integration of Renewable Energy Source (RES), network reconfiguration, and expansion planning, have been suggested in the literature for achieving ELM. The optimal RES integration (also referred to as Distributed Generation (DG)) is one of the globally accepted techniques to achieve minimization of electrical losses. Therefore, first, the locations to accommodate these DGs are obtained by implementing two indexes, namely Index-1 for single DG and Index-2 for multiple DGs. Second, a Constriction Factor-based Particle Swarm Optimization (CF-PSO) technique is applied to obtain an optimal sizing(s) of the DGs for achieving the ELM. Third, the RA of the EDS is performed using the optimal location(s) and sizing(s) of the RESs (i.e., Solar photovoltaic (SPV) and Wind Turbine Generator (WTG)). Moreover, a Battery Storage System (BSS) is also incorporated optimally with the RESs to further achieve the ELM and to improve the system’s reliability. The result analysis is performed by considering the power output rating of WTG-GE’s V162-5.6MW (IECS), SPV-Sunpower’s SPR-P5-545-UPP, and BSS-Freqcon’s BESS-3000 (i.e., Battery Energy Storage System 3000), which are provided by the corresponding manufacturers. According to the outcomes of the study, the results are found to be coherent with those obtained using other techniques that are available in the literature. These results are considered for the RA of the EDS. RA is further analyzed considering the uncertainties in reliability data of WTG and SPV, including the failure rate and the repair time. The RA of optimally placed DGs is performed by considering the electrical loss minimization. It is inferred that the reliability of the EDS improves by contemplating suitable reliability data of optimally integrated DGs.
History
Volume
13Issue
21Start Page
1End Page
30eISSN
1996-1073Publisher
MDPI AGPublisher DOI
Full Text URL
Additional Rights
CC BY 4.0Language
enPeer Reviewed
- Yes
Open Access
- Yes
Acceptance Date
2020-10-22External Author Affiliations
AA Industries, Institute of Technology and Science, Indian Institute of Technology (BHU), IndiaAuthor Research Institute
- Centre for Intelligent Systems
Era Eligible
- Yes