Intercomparison dripper testing within the INITL

journal contribution
posted on 2018-07-24, 00:00 authored by Richard KoechRichard Koech, B Molle, AP de Camargo, P Dimaiolo, M Audouard, E Saretta, JA Frizzone, D Pezzaniti, G Benhu
The International Network of Irrigation Testing Laboratories (INITL) undertook a laboratory intercomparison testing exercise of three sets of drippers in the period 2013 and 2014. The four testing facilities that participated in this exercise are based in following countries: Australia, Brazil, France and China. The objective of the testing programme was to compare results from different independent testing facilities to enable individual laboratories identify potential opportunities for improvement of their performances. This would also facilitate the INITL to make proposals for harmonisation of the testing methods. The maximum coefficient of variation, cv, at the manufacturer's recommended operating pressure of 100 kPa, was found to be 3.76%, which was significantly smaller than the 7% recommended by ISO 9261 [5] as the maximum allowable variation of the flow rate of the test sample. The emitter exponent was determined to be approximately 0.5 which is consistent with results obtained from past studies. At the operating pressure of 100 kPa, it was found that although the average flow rates from the participating laboratories were similar, there was a difference in the dispersion of data. Datasets for the 4 L h 1 dripper model fitted a normal distribution model, while on the other hand, some datasets for the 2 and 8 L h 1 dripper models were not normally distributed. A higher dispersion of measurements can be interpreted as a higher instability of the testing conditions. The variance for the 2 L h 1 dripper model was found to be homogeneous, while non-homogeneous for the other two models. The latter implies that at least one of the laboratories presented an uncertainty of measurement significantly different from the others. The measurement uncertainty undertaken in this study demonstrated that there were opportunities to improve the measurement process. Recommendations and suggestions for harmonisation of test procedures and improvements in individual laboratories are also identified in this paper.

History

Volume

46

Issue

A

Start Page

1

End Page

11

Number of Pages

11

ISSN

0955-5986

Peer Reviewed

  • Yes

Open Access

  • No

Acceptance Date

2015-08-13

Era Eligible

  • Yes

Journal

Flow Measurement and Instrumentation

Usage metrics

    CQUniversity

    Exports

    RefWorks
    BibTeX
    Ref. manager
    Endnote
    DataCite
    NLM
    DC