File(s) not publicly available
Clinical outcome of preimplantation genetic diagnosis and screening using next generation sequencing
journal contribution
posted on 2018-10-23, 00:00 authored by Y Tan, X Yin, S Zhang, H Jiang, K Tan, J Li, B Xiong, F Gong, C Zhang, X Pan, Gabor Vajta© 2014 Tan et al.Background: Next generation sequencing (NGS) is now being used for detecting chromosomal abnormalities in blastocyst trophectoderm (TE) cells from in vitro fertilized embryos. However, few data are available regarding the clinical outcome, which provides vital reference for further application of the methodology. Here, we present a clinical evaluation of NGS-based preimplantation genetic diagnosis/screening (PGD/PGS) compared with single nucleotide polymorphism (SNP) array-based PGD/PGS as a control.Results: A total of 395 couples participated. They were carriers of either translocation or inversion mutations, or were patients with recurrent miscarriage and/or advanced maternal age. A total of 1,512 blastocysts were biopsied on D5 after fertilization, with 1,058 blastocysts set aside for SNP array testing and 454 blastocysts for NGS testing. In the NGS cycles group, the implantation, clinical pregnancy and miscarriage rates were 52.6% (60/114), 61.3% (49/80) and 14.3% (7/49), respectively. In the SNP array cycles group, the implantation, clinical pregnancy and miscarriage rates were 47.6% (139/292), 56.7% (115/203) and 14.8% (17/115), respectively. The outcome measures of both the NGS and SNP array cycles were the same with insignificant differences. There were 150 blastocysts that underwent both NGS and SNP array analysis, of which seven blastocysts were found with inconsistent signals. All other signals obtained from NGS analysis were confirmed to be accurate by validation with qPCR. The relative copy number of mitochondrial DNA (mtDNA) for each blastocyst that underwent NGS testing was evaluated, and a significant difference was found between the copy number of mtDNA for the euploid and the chromosomally abnormal blastocysts. So far, out of 42 ongoing pregnancies, 24 babies were born in NGS cycles; all of these babies are healthy and free of any developmental problems.Conclusions: This study provides the first evaluation of the clinical outcomes of NGS-based pre-implantation genetic diagnosis/screening, and shows the reliability of this method in a clinical and array-based laboratory setting. NGS provides an accurate approach to detect embryonic imbalanced segmental rearrangements, to avoid the potential risks of false signals from SNP array in this study.
Funding
Other
History
Volume
3Issue
1Start Page
1End Page
9Number of Pages
9ISSN
2047-217XPublisher
BioMed CentralPublisher DOI
Additional Rights
CC BY 2.0Peer Reviewed
- Yes
Open Access
- Yes
Acceptance Date
2014-11-11External Author Affiliations
Central South University; Shenzhen Municipal Birth Defect Screening Project Lab; National Engineering and Research Center of Human Stem Cell; Reproductive & Genetic Hospital of CITIC Xiangya; Guangdong Enterprise Key Laboratory of Human Disease Genomics; Key Laboratory of Stem Cell and Reproductive Engineering, Ministry of HealthEra Eligible
- Yes
Journal
GigaScienceUsage metrics
Categories
Keywords
Licence
Exports
RefWorksRefWorks
BibTeXBibTeX
Ref. managerRef. manager
EndnoteEndnote
DataCiteDataCite
NLMNLM
DCDC