File(s) not publicly available
A randomised pilot equivalence trial to evaluate diamagnetically enhanced transdermal delivery of key ground substance components in comparison to an established transdermal non-steroidal anti-inflammatory formulation in males with prior knee injury
journal contribution
posted on 2020-02-17, 00:00 authored by B Vicenzino, P Lawrenson, A Khan, A Stephenson, Luke HealesLuke Heales, HAE Benson, A WrightThis is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. Objective This pilot study assessed the efficacy of a knee guard device, which used magnetophoresis to transdermally deliver Glucosamine, Chondroitin and Hyaluronic Acid in a cohort of individuals with prior knee injury. The aim was to determine if the change in physical function and pain with the knee guard device was equivalent to the change produced by an established topical NSAID formulation containing diclofenac sodium 1%. Methods A randomized, controlled, equivalence trial evaluated outcomes following treatment with the knee guard device or NSAID formulation. The study recruited 114 male participants (aged 40–55 years). Participants were randomly allocated to wear the knee guard device or to use a NSAID gel daily for two weeks. The primary outcomes were the knee injury osteoarthritis function score (KOOS-F) and an aggregated function score (AFS). The lower extremity functional scale (LEFS), pain numerical rating scale (PNRS), global rating of change (GROC) and other KOOS scores were also evaluated. Results Multiple linear regression analyses indicated that there were no significant differences between the interventions for changes in the primary outcomes of AFS and KOOS_F. The 95% confidence interval (-2.89 to 5.15) of the estimated treatment difference for KOOS-F was within the lower (-5.61) and upper (5.61) bounds of the 7% equivalence margin for that measure, The mean value for the AFS was within, but the 95% CI (-3.11 to 7.37) exceeded the 7% equivalence margin (-2.97 to 2.97) for that measure. There was a significant difference in PNRS, which favored the knee guard device. Conclusion The knee guard device demonstrated equivalence for the KOOS-F measure but not the AFS measure of function over the two week trial period when compared to a widely available NSAID gel that has been shown to be superior to placebo. The knee guard produced a greater reduction in pain report (p = 0.002) than the NSAID gel. Users of the knee guard device experienced more skin irritation than participants using the NSAID gel. Further research is required to fully evaluate the therapeutic potential of this innovative treatment approach. © 2019 Vicenzino et al.
Funding
Category 3 - Industry and Other Research Income
History
Volume
14Issue
2Start Page
1End Page
13Number of Pages
13eISSN
1932-6203Publisher
Public Library of Science, USAPublisher DOI
Additional Rights
CC BY 4.0Peer Reviewed
- Yes
Open Access
- Yes
Acceptance Date
2019-01-24External Author Affiliations
Curtin UniversityEra Eligible
- Yes
Journal
PLoS ONEUsage metrics
Categories
Keywords
Licence
Exports
RefWorksRefWorks
BibTeXBibTeX
Ref. managerRef. manager
EndnoteEndnote
DataCiteDataCite
NLMNLM
DCDC